Addressable Fire Alarm System

Category:

Description

  • Identify the exact location of the fire incidence
  • Aids swift action to curtail fire
  • Detection devices are designed to detect actual fire instances only, decreasing the chances of fire alarms
  • Cost effective solution to early fire detection

Product Overview

Ceasefire’s revolutionary Addressable Fire Alarm System is a best in class detection and alarm system to safeguard the fire safety of a premises. The system senses fire in the nascent stage & identifies the exact location of the fire. The system is an amalgamation of a highly advanced control panel and an array of fire detection devices.

As the name suggests, this system is addressable system i.e. each detection device of this system is identifiable. In case of a fire incidence when the alarm goes off, the main panel is able to trace the exact system component that has gone off thus enabling to track the fire location at the precise point so that there is no delay in firefighting.

This system is an ideal fire detection & alarm system for large premises that spread over a vast area

Product Features

Optional Control Panels

1. Addressable Panel (1-2 loops)

Features

  • 16 zonal LED indicators
  • 2 programmable sounder circuits
  • 5 programmable inputs
  • 3 programmable relays
  • 3A power supply
  • Large graphic display
  • Real time clock
  • Certified to EN54-2/ EN54-4
  • Up to 512 additional programmable I/O via HFP I/O modules
  • Powerful, network wide cause and effects
  • Sensitivity adjustment and Drift Compensation
  • Can be networked with HFP control panels
  • Compatible with HFP and HFP AP-CRL repeaters
  • Stores 500 last events in event log
  • Dial up modem connection available
  • Compact, stylish enclosure
  • Installer friendly, removable equipment chassis
  • Different language and character set variants available
  • Fully EN54-2 and EN54-4 compliant
  • 1 or 2 loop versions as standard
  • Larger enclosure available
  • 0, 16, 48 or 96 zone indicators
  • Network up to 64 panels/repeaters
  • 4 programmable sounder circuits as standard
  • 5.25 amp power supply to EN54 part 4
  • Large graphic display
  • In-built help and alarm information screens
  • Certified to EN54-2 / EN54-4
  • Real time clock
  • Supports loop powered sounders and beacons
  • Sensitivity adjustment and Drift Compensation
  • Soft-touch tactile buttons
  • 2 programmable function buttons
  • 3 programmable front panel mounted LEDs
  • Improved Front loading printer (optional)
  • Up to 512 programmable inputs/outputs per panel via 2 wire RS485 serial link (optional)
  • Simple Windows® graphical configuration utility

2. Addressable Panel (2-8 loops)

Features

  • Compliant with EN54-2, EN54-4
  • 2 to 8 loop or 2 to 16 loop versions
  • 500mA loop current
  • 4 programmable sounder circuits each rated at 2.5 A
  • 5.25 A or 10.25 A, power supply options
  • 3 programmable inputs
  • 5 programmable relay outputs
  • Up to 512 programme Input/ Output via optional plug in and serially connected expansion cards
  • Hard wired fire and fault routing inputs and outputs
  • Modular electronics
  • Over 4000 sub address points per panel
  • Option to “invert” inputs and outputs
  • Powerful, standard configuration templates
  • Network up to 128 panels
  • Configurable via USB port to PC or memory stick
  • 2 ancillary serial ports

3. SMARTX Single Loop Control Panel

Features

  • One Loop Analogue Addressable control panels
  • 2 Conventional Zones (Maximum 20 detectors per zone)
  • Advanced ASR (Active Signal Reshaping) loop detector for improved noise immunity in harsh environments
  • Day/Night operation, separate profile for each week day. Changes ESP Sensitivity and Alarm verification
  • Manual add/remove of loop devices (easy search with Ceasefire part number)
  • 2 Supervised Siren Outputs
  • Siren pattern selection for on board (switched) and loop devices
  • Storage of up to 2,000 log events
  • Built-in communicator (Ademco Contact ID)
  • System LED indications: Power, Fault, Alarm, Pre Alarm, Delay Active, Sirens Silenced, On Test

Technical Specification

Features 1 Loop
Control Panel
2 Loop
Control Panel
4 Loop
Control Panel
8 Loop
Control Panel
Enclosure Steel Ip30 Steel Ip30 Steel Ip30 Steel Ip30
Operating
Temperature
0°C to 45°C 0°C to 45°C 0°C to 45°C 0°C to 45°C
Operating Humidity 95% (max) 95% (max) 95% (max) 95% (max)
Cable Entries
(20mm Knockouts)
7 × top & 7 × rear 18 × top, 9 × top rear
and 2 × bottom
18 × top, 9 × top
rear and 2 × bottom
36 × top, 9 × top
rear and 2 × bottom
Mains Supply 230V, +10%, –15%, 50-
60 Hz AC, 0.4A (max)
220-240V, +10%, –15%,
47-63 Hz AC, 1A (max)
220-240V, +10%, –15%,
47-63 Hz AC, 1A (max)
220-240V, +10%, –15%,
47-63 Hz AC, 1A (max)
Battery Capacity 24V 4Ah Internal (min),
24V 7Ah Internal (max)
24V 4Ah Internal (min),
24V 17Ah Internal (max)
24V 4Ah Internal (min),
24V 17Ah Internal (max)
2 × 24V 4Ah Internal (min),
2 × 24V 38Ah Internal (max)
Charging Current 0.4A DDP Temperature
Compensated
2.4A DDP Temperature
Compensated
2.4A DDP Temperature
Compensated
2 × 2.4A DDP
Temp. Compensated
Power Supply Separate 24V DC, 2A High
Efficiency Switched Mode
Separate 24V DC, 4A
Off-Line Switched Mode
Separate 24V DC, 5A
Off-Line Switched Mode
4 × Separate 24V DC, 5A
Off-Line Switched Mode
Number Of Fire
Zones
100 max (250 when
networked)
200 max across 2
loops(100 when
networked)
200 max across 2 loops
(100 when networked)
200 max across 4 loops
(1000 when networked)
Number Of Loops 1 1 to 2 1 to 4 1 to 8
Loop Current 500mA (max) 500mA per loop (max) 500mA per loop (max) 500mA per loop (max)
Protocol ESP (Enhanced System
Protocol)
ESP (Enhanced System
Protocol)
ESP (Enhanced System
Protocol)
ESP (Enhanced System
Protocol)
Sounder Outputs 2 × 1A Programmable 2 × 1A Programmable 4 × 1A
Programmable
8 × 1A Programmable
Relay Outputs 2 × 1A 30V AC/DC (max),
10mA, 5V (min)
Programmable
2 × 1A 30V AC/DC
(max), 10mA, 5V (min)
Programmable
2×1A 30V AC/DC (max),
10mA, 5V (min)
Programmable
4 × 1A 30V AC/DC (max),
10mA, 5V (min) Programmable
Open Collector
Outputs
2 × Programmable 1A
30V DC (max)
8 × Programmable
10mA 30V DC (max)
8 × Programmable
10mA 30V DC (max)
16 × Programmable
10mA 30V DC (max)
Digital Inputs 8 × Programmable 8 × Programmable 8 × Programmable 16 × Programmable
Auxiliary Supply
Outputs
24V DC, 500mA 24V DC, 500mA 24V DC, 500mA 2 x 24V DC, 500mA
Weight (excluding
Batteries)
5 Kg 10.5 Kg / 12 Kg (/D) 10.5 Kg / 12 Kg (/D) 23 Kg
Dimensions (mm) H345 × W320 × D88 H475 × W450 × D125
(H475 × W450 ×
D190 (/D))
H475 × W450 × D125
(H475 × W450 × D190 (/D))
H950 × W450 × D190

Application Areas

  • Office & Factories
  • Schools & Colleges
  • Community Centres
  • Server Rooms
  • Residential Buildings
  • Hotels & Restaurants

Reviews

There are no reviews yet.

Be the first to review “Addressable Fire Alarm System”