The conventional fire alarm system is a time-tested fire alarm system; this makes it one of the most reliable systems for ensuring fire safety of a premises. The Ceasefire’s Conventional Fire Alarm System is a state-of-art system which comprises of a control panel and a range of fire detectors and devices interacting with it.
The conventional system divides the premises into distinct zones. Each zone has its own set of detectors & alarm systems.
The detection & alarm devices are spread across the premises and catch the early signs fire. In case of a fire incidence the system identifies the zone in which the fire has occurred.
Product Features
- Fully certified to BS EN54-2 and BS EN54-4
- 2-wire and standard versions in 2,4 or 8 zones
- Compatible for use on BS5839: Part 1: 2013 installations
- 2-wire repeaters and ancillary boards
- Fully programmable
- Simple, single board construction
- Installer friendly
- Compatible with wide range of detection devices
- Two monitored sounder outputs
- 3 Amp power supply
- Auxiliary power output
Technical Specification
Features | 2 Zone Conventional Panel |
4 Zone Conventional Panel |
8 Zone Conventional Panel |
2 Zone Conventional Repeater Panel |
4 Zone Conventional Repeater Panel |
8 Zone Conventional Repeater Panel |
---|---|---|---|---|---|---|
Enclosure | 1.2mm Steel | 1.2mm Steel | 1.2mm Steel | 1.2mm Steel | 1.2mm Steel | 1.2mm Steel |
Operating Temperature |
–5°C to +50°C | –5°C to +50°C | –5°C to +50°C | –5°C to +50°C | –5°C to +50°C | –5°C to +50°C |
Operating Humidity | Cable Entries (20 Mm Knockouts): 12 × top, 12 × top rear, 1× lefthand side, 1 × right hand side |
Cable Entries (20 Mm Knockouts): 12 × top, 12 × top rear, 1× lefthand side, 1 × right hand side |
Cable Entries (20 Mm Knockouts): 12 × top, 12 × top rear, 1× lefthand side, 1 × right hand side |
— | — | — |
Supply Voltage | 230V AC (+10% / –15%) | 230V AC (+10% / –15%) | 230V AC (+10% / –15%) | 230V AC (+10% / –15%) | 230V AC (+10% / –15%) | 230V AC (+10% / –15%) |
Power Supply Dc Rating |
24V 3A | 24V 3A | 24V 3A | 24V 3A | 24V 3A | 24V 3A |
Battery Capacity | 7Ah 12V (2 per panel) | 7Ah 12V (2 per panel) | 7Ah 12V (2 per panel) | — | — | — |
Number Of Fire Zones |
2 | 4 | 8 | 2 | 4 | 8 |
Sounder Outputs | 2 × 0.5A (max 1.6A over all outputs) |
2 × 0.5A (max 1.6A over all outputs) |
2 × 0.5A (max 1.6A over all outputs) |
2 × 0.5A (max 1.6A over all outputs) |
2 × 0.5A (max 1.6A over all outputs) |
2 × 0.5A (max 1.6A over all outputs) |
Contact Rating (Fault / Local Fire / Fire) |
30V DC 1A | 30V DC 1A | 30V DC 1A | — | 30V DC 1A | 30V DC 1A |
Detection Zone Current |
1.6mA | 1.6mA | 1.6mA | 1.6mA | 1.6mA | 1.6mA |
Detection Zone End Of Line Resistor |
6.8k ohm 5% | 6.8k ohm 5% | 6.8k ohm 5% | 6.8k ohm 5% | 6.8k ohm 5% | 6.8k ohm 5% |
Sounder Output End Of Line Resistor |
10k ohm 5% | 10k ohm 5% | 10k ohm 5% | 10k ohm 5% | 10k ohm 5% | 10k ohm 5% |
Contact Rating (fault / Local Fire / Fire) |
— | — | — | 30V DC 1A | — | — |
Detection Zone Current |
— | — | — | 1.6mA | 1.6mA | 1.6mA |
Weight | 5.5Kg | 5.5Kg | 5.5Kg | 5.5Kg | 5.5Kg | 5.5Kg |
Dimensions (mm) | 385(W) × 310(H) × 92(D) | 385(W) × 310(H) × 92(D) | 385(W) × 310(H) × 92(D) | 385(W) × 310(H) × 92(D) | 385(W) × 310(H) × 92(D) | 385(W) × 310(H) × 92(D) |
Features | Photoelectric Smoke Detector |
Combined Heat Detector |
Conventional Beacon |
Combined Sounder/Strobe |
Conventional Call Point |
Beam Smoke Detector |
Mounting Base |
---|---|---|---|---|---|---|---|
SKU No. | 1CD1101 | 1CD1102 | 1CD1212 | 1CD1207 | 1CD1201 | 1CD1301 | 1CD1106 |
Disposable Chamber | Yes | — | — | — | — | — | — |
Operating Voltage | 9.5 – 30 Vd.c. | 9.5 – 30 Vd.c. | 17 – 41Vd.c. | 9 – 30 VDC | — | 15 – 33Vd.c. | — |
Quiescent Current (typ) |
35m A | 35m A | 4.3μA (5.0μA max) | — | — | 240m A | — |
Maximum Current Alarm |
40mA | 40mA | — | — | — | 50mA | — |
Remote Indicator Drive |
20 mA(max) / 9.5 – 14mA (typ) |
20 mA(max) / 9.5 – 14mA (typ) |
— | — | — | — | — |
Operating Temperature Range |
–10°C to +50°C | –10°C to +50°C | –10°C to +50°C | –20°C to +60°C | –10°C to +50°C | –10°C to +50°C | –10°C to +50°C |
Storage Temperature Range |
–30°C to +60°C | –30°C to +70°C | –30°C to +60°C | — | –30°C to +70°C | –30°C to +70°C | –30°C to +60°C |
Maximum Humidity | 95%RH – Non- Condensing (at 40°C) |
95%RH – Non- Condensing (at 40°C) |
95%RH – Non- Condensing (at 40°C) |
75%RH – Non Condensing (at 40°C) |
95%RH – Non- Condensing (at 40°C) |
95%RH – Non- Condensing (at 40°C) |
95%RH – Non- Condensing (at 40°C) |
Ingress Protection Rating |
Ip42 | Ip63 | — | — | Ip24 | — | — |
Colour / Case Material |
Ivory White / ABS | Ivory White / Polycarbonate |
Ivory White / ABS | — | Red / ABS | Ivory White / ACS | Ivory or White / ABS |
Weight (g) | 95 | — | 88 | — | (Flush Mount) 110 (Surface Mount with Back Box) 161 |
(Receiver) 685 (Emitter) 600 |
— |
Compatible Bases |
CF-YBN-R/6, CF-YBO-R/6R, CFYBO- R/6RS, CF-YBN-R/6SK, CFYBO- R/6RN, CF-YBO-R/6PA |
CF-YBN-R6 CF-YBO-R/6R CFYBN- R/6SK CF-YBO-R/6RS CFYBO- R/6RN CF-YBO-R/6PA |
— | — | — | — | — |
Base Heights (mm) | 8, 13 | 8, 13 | — | — | — | — | — |
Base Fixing Centres (mm) |
48 – 74 | 48 – 74 | 48 – 74 | — | — | — | 48 – 74 |
Approvals | LPCB EN54:2000 Part 7 | LPCB (EN54:2000) Class A1 & A1R (CFDCD- AE3) Class C & CR (CF-DCD-CE3) Class C & CR (CF-DCD-CE3) (G204045) |
— | — | — | LPCB (EN54:12) | — |
Lens Colour | — | — | Transparent Red | — | — | — | — |
Operating Current | — | — | — | min 46mA (dependant on tone selected) max 70mA (dependent on tone selected) |
— | — | 9.5 – 30Vd.c. |
Nominal Flash Energy |
— | — | — | 1W | — | — | — |
Flash Rate | — | — | — | 60 minutes | — | — | — |
Maximum Sound Output (at 24vdc) |
— | — | — | 112dB(A) at 1 metre (dependent on tone selected) |
— | — | — |
IP Rating | — | — | — | IP45 (with internal back box-as standard) IP66 (with external back box-sold separately) |
— | — | — |
Nominal Operating Resistance |
— | — | — | — | 470 ohms | — | — |
Operation Range | — | — | — | — | — | 5 – 100 (between emitter & receiver) |
— |
Sensitivity Range | — | — | — | — | — | 25%, 50% 60% obscuration (selectable) |
— |
Line Continuity Options (INT. Kit) |
— | — | — | — | — | Schottky / Zener | — |
Weight (g) | — | — | — | — | — | — | 51 |
Diameter (mm) | — | — | — | — | — | — | 100 |
Height (mm) | — | — | — | — | — | — | 8 |
Features | Mounting Base | IR Flame Detector | Reflective Beam Smoke Detector |
---|---|---|---|
SKU No. | 1CD1106 | 1CD1606 | 1CD1305 |
Operating Voltage | — | 14 – 30Vd.c. | 15 – 30Vd.c. |
Quiescent Current (typ) |
— | — | 350μ A |
Maximum Current Alarm |
— | — | 50μA |
Operating Temperature Range |
-10°C to + 50°C | -10°C to + 50°C | -10°C to + 50°C |
Storage Temperature Range |
-30°C to + 60°C | –20°C to +65°C | –30°C to +70°C |
Maximum Humidity | 95%RH – Non Condensing (at 40°C) |
95%RH – Non Condensing (at 40°C) |
95%RH – Non Condensing (at 40°C) |
Ingress Protection Rating |
— | IP65 | — |
Colour / Case Material |
Ivory or White / ABS | Blue / Die-Cast Zinc Alloy (Za12) |
Ivory White / ABS |
Weight (g) | 51 g | 2 Kg | (Emitter) 700 (Reflector) 50 |
Approvals | — | — | LPCB BS5839 Part 5 PrEN54 Part 12 |
Operation Range | — | — | 5 – 30 |
Sensitivity Range |
— | — | 30% |
Line Continuity Options (int. Kit) |
— | — | Schottky / Zener |
Alarm Current (selected Via By Dil Switched) |
— | 3 – 28mA | — |
Test Signal Voltage |
— | 14 – 30Vd.c. | — |
Relay Contact Ratings |
— | Current 1.0A (max) Voltage 50Vd.c. (max) Power 30W (max) (resistive loads only) |
— |
Field Of View | — | 90° min. Cone | — |
Operating Wavelength Band |
— | IR (0.75 – 2.7mm) | — |
Power Up Time | — | 2 Seconds (max) | — |
Weight (g) / Diameter (mm) / Height (mm) |
51 / 100 / 8 | — | — |
Base Fixing Centres (mm) |
48 ~ 74 | — | — |
Operating Current | 9.5 – 30Vd.c. | — | — |
Maximum Wire Thickness |
2.5mm square Cables | — | — |
Diameter | 100 mm | — | — |
Height | 8 | — |
Application Areas
- Office & Factories
- Schools & Colleges
- Community Centres
- Server Rooms
- Residential Buildings
- Hotels & Restaurants