Conventional Fire Alarm System

Category:

Description

  • Ideal alarm system for small set-ups
  • Identifies the zone in which the fire incidence has occurred
  • A technological advantage over standalone detectors
  • Detection devices are designed to detect actual fire instances only, decreasing the chances of fire alarms
  • One of the most cost effective alarm solution
  • Simple setup, no configuration required

Product Overview

The conventional fire alarm system is a time-tested fire alarm system; this makes it one of the most reliable systems for ensuring fire safety of a premises. The Ceasefire’s Conventional Fire Alarm System is a state-of-art system which comprises of a control panel and a range of fire detectors and devices interacting with it.

The conventional system divides the premises into distinct zones. Each zone has its own set of detectors & alarm systems.

The detection & alarm devices are spread across the premises and catch the early signs fire. In case of a fire incidence the system identifies the zone in which the fire has occurred.

Product Features

  • Fully certified to BS EN54-2 and BS EN54-4
  • 2-wire and standard versions in 2,4 or 8 zones
  • Compatible for use on BS5839: Part 1: 2013 installations
  • 2-wire repeaters and ancillary boards
  • Fully programmable
  • Simple, single board construction
  • Installer friendly
  • Compatible with wide range of detection devices
  • Two monitored sounder outputs
  • 3 Amp power supply
  • Auxiliary power output

Technical Specification

Features 2 Zone
Conventional Panel
4 Zone
Conventional Panel
8 Zone
Conventional Panel
2 Zone Conventional
Repeater Panel
4 Zone Conventional
Repeater Panel
8 Zone Conventional
Repeater Panel
Enclosure 1.2mm Steel 1.2mm Steel 1.2mm Steel 1.2mm Steel 1.2mm Steel 1.2mm Steel
Operating
Temperature
–5°C to +50°C –5°C to +50°C –5°C to +50°C –5°C to +50°C –5°C to +50°C –5°C to +50°C
Operating Humidity Cable Entries (20 Mm Knockouts):
12 × top, 12 × top rear, 1× lefthand
side, 1 × right hand side
Cable Entries (20 Mm Knockouts):
12 × top, 12 × top rear, 1× lefthand
side, 1 × right hand side
Cable Entries (20 Mm Knockouts):
12 × top, 12 × top rear, 1× lefthand
side, 1 × right hand side
Supply Voltage 230V AC (+10% / –15%) 230V AC (+10% / –15%) 230V AC (+10% / –15%) 230V AC (+10% / –15%) 230V AC (+10% / –15%) 230V AC (+10% / –15%)
Power Supply Dc
Rating
24V 3A 24V 3A 24V 3A 24V 3A 24V 3A 24V 3A
Battery Capacity 7Ah 12V (2 per panel) 7Ah 12V (2 per panel) 7Ah 12V (2 per panel)
Number Of Fire
Zones
2 4 8 2 4 8
Sounder Outputs 2 × 0.5A (max 1.6A
over all outputs)
2 × 0.5A (max 1.6A
over all outputs)
2 × 0.5A (max 1.6A
over all outputs)
2 × 0.5A (max 1.6A
over all outputs)
2 × 0.5A (max 1.6A
over all outputs)
2 × 0.5A (max 1.6A
over all outputs)
Contact Rating (Fault /
Local Fire / Fire)
30V DC 1A 30V DC 1A 30V DC 1A 30V DC 1A 30V DC 1A
Detection Zone
Current
1.6mA 1.6mA 1.6mA 1.6mA 1.6mA 1.6mA
Detection Zone End
Of Line Resistor
6.8k ohm 5% 6.8k ohm 5% 6.8k ohm 5% 6.8k ohm 5% 6.8k ohm 5% 6.8k ohm 5%
Sounder Output End
Of Line Resistor
10k ohm 5% 10k ohm 5% 10k ohm 5% 10k ohm 5% 10k ohm 5% 10k ohm 5%
Contact Rating (fault /
Local Fire / Fire)
30V DC 1A
Detection Zone
Current
1.6mA 1.6mA 1.6mA
Weight 5.5Kg 5.5Kg 5.5Kg 5.5Kg 5.5Kg 5.5Kg
Dimensions (mm) 385(W) × 310(H) × 92(D) 385(W) × 310(H) × 92(D) 385(W) × 310(H) × 92(D) 385(W) × 310(H) × 92(D) 385(W) × 310(H) × 92(D) 385(W) × 310(H) × 92(D)

 

 

Features Photoelectric
Smoke Detector
Combined
Heat Detector
Conventional
Beacon
Combined
Sounder/Strobe
Conventional
Call Point
Beam
Smoke Detector
Mounting
Base
SKU No. 1CD1101 1CD1102 1CD1212 1CD1207 1CD1201 1CD1301 1CD1106
Disposable Chamber Yes
Operating Voltage 9.5 – 30 Vd.c. 9.5 – 30 Vd.c. 17 – 41Vd.c. 9 – 30 VDC 15 – 33Vd.c.
Quiescent
Current (typ)
35m A 35m A 4.3μA (5.0μA max) 240m A
Maximum
Current Alarm
40mA 40mA 50mA
Remote
Indicator Drive
20 mA(max) / 9.5
– 14mA (typ)
20 mA(max) / 9.5
– 14mA (typ)
Operating
Temperature Range
–10°C to +50°C –10°C to +50°C –10°C to +50°C –20°C to +60°C –10°C to +50°C –10°C to +50°C –10°C to +50°C
Storage
Temperature Range
–30°C to +60°C –30°C to +70°C –30°C to +60°C –30°C to +70°C –30°C to +70°C –30°C to +60°C
Maximum Humidity 95%RH – Non-
Condensing (at 40°C)
95%RH – Non-
Condensing (at 40°C)
95%RH – Non-
Condensing (at 40°C)
75%RH – Non
Condensing (at 40°C)
95%RH – Non-
Condensing (at 40°C)
95%RH – Non-
Condensing (at 40°C)
95%RH – Non-
Condensing (at 40°C)
Ingress
Protection Rating
Ip42 Ip63 Ip24
Colour / Case
Material
Ivory White / ABS Ivory White /
Polycarbonate
Ivory White / ABS Red / ABS Ivory White / ACS Ivory or White / ABS
Weight (g) 95 88 (Flush Mount) 110 (Surface
Mount with Back Box) 161
(Receiver) 685
(Emitter) 600
Compatible
Bases
CF-YBN-R/6, CF-YBO-R/6R, CFYBO-
R/6RS, CF-YBN-R/6SK, CFYBO-
R/6RN, CF-YBO-R/6PA
CF-YBN-R6 CF-YBO-R/6R CFYBN-
R/6SK CF-YBO-R/6RS CFYBO-
R/6RN CF-YBO-R/6PA
Base Heights (mm) 8, 13 8, 13
Base Fixing Centres
(mm)
48 – 74 48 – 74 48 – 74 48 – 74
Approvals LPCB EN54:2000 Part 7 LPCB (EN54:2000) Class A1 & A1R (CFDCD-
AE3) Class C & CR (CF-DCD-CE3)
Class C & CR (CF-DCD-CE3) (G204045)
LPCB (EN54:12)
Lens Colour Transparent Red
Operating Current min 46mA (dependant on tone
selected) max 70mA
(dependent on tone selected)
9.5 – 30Vd.c.
Nominal Flash
Energy
1W
Flash Rate 60 minutes
Maximum Sound
Output (at 24vdc)
112dB(A) at 1 metre
(dependent on tone selected)
IP Rating IP45 (with internal back box-as
standard) IP66 (with external
back box-sold separately)
Nominal Operating
Resistance
470 ohms
Operation Range 5 – 100 (between
emitter & receiver)
Sensitivity Range 25%, 50% 60%
obscuration (selectable)
Line Continuity
Options (INT. Kit)
Schottky / Zener
Weight (g) 51
Diameter (mm) 100
Height (mm) 8

 

Features Mounting Base IR Flame Detector Reflective Beam
Smoke Detector
SKU No. 1CD1106 1CD1606 1CD1305
Operating Voltage 14 – 30Vd.c. 15 – 30Vd.c.
Quiescent
Current (typ)
350μ A
Maximum
Current Alarm
50μA
Operating
Temperature Range
-10°C to + 50°C -10°C to + 50°C -10°C to + 50°C
Storage
Temperature Range
-30°C to + 60°C –20°C to +65°C –30°C to +70°C
Maximum Humidity 95%RH – Non
Condensing (at 40°C)
95%RH – Non
Condensing (at 40°C)
95%RH – Non
Condensing (at 40°C)
Ingress
Protection Rating
IP65
Colour / Case
Material
Ivory or White / ABS Blue / Die-Cast Zinc
Alloy (Za12)
Ivory White / ABS
Weight (g) 51 g 2 Kg (Emitter) 700
(Reflector) 50
Approvals LPCB BS5839 Part
5 PrEN54 Part 12
Operation Range 5 – 30
Sensitivity
Range
30%
Line Continuity
Options (int. Kit)
Schottky / Zener
Alarm Current (selected
Via By Dil Switched)
3 – 28mA
Test Signal
Voltage
14 – 30Vd.c.
Relay Contact
Ratings
Current 1.0A (max) Voltage
50Vd.c. (max) Power 30W
(max) (resistive loads only)
Field Of View 90° min. Cone
Operating
Wavelength Band
IR (0.75 – 2.7mm)
Power Up Time 2 Seconds (max)
Weight (g) / Diameter
(mm) / Height (mm)
51 / 100 / 8
Base Fixing Centres
(mm)
48 ~ 74
Operating Current 9.5 – 30Vd.c.
Maximum Wire
Thickness
2.5mm square Cables
Diameter 100 mm
Height 8

Application Areas

  • Office & Factories
  • Schools & Colleges
  • Community Centres
  • Server Rooms
  • Residential Buildings
  • Hotels & Restaurants