Description
- Fights Class A, B, C, Fires and electrically started fires
- Electronics and environment-friendly
- Superior Extinguishing agent: HFC227ea
- Can be triggered manually or automatically
- 24 hour protection
Product Overview
The waterless Ceasefire HFC 227ea Flooding System – M is a revolutionary firefighting System. Designed and equipped to initiate firefighting within seconds of the fire being detected, this automated flooding system safeguards the entire area. What’s more, since HFC227ea is green in nature, this extinguishing agent ensures that the fire is put out without causing any collateral damage to the premises, expensive equipment, or the earth.
Backed by in-depth studies of common applications of the HFC227ea flooding system in the Indian market, the Ceasefire Design Cell has created 8 pre-fabricated variants of the system, which can be installed in rooms of different sizes. They are designed with utmost precision to international quality standards, and come with complete sets of accessories to fullfil all the requirements of a fire-prone micro environment.
Product Features
Classification : Works on class A, B, C fires and fires involving electrically-charged devices. Effective on a wide range of flammable and combustible materials.
Electronics-Friendly: Shown to be electrically non-conductive and is safe for electrically charged equipment, it is kinder on electronics than the majority of extinguishing agents available in the market.
Ozone, Environment-Friendly: Being a clean-agent, this is an eco-friendly alternative to chemical and water-based extinguishing systems. As HFC 227ea® already exists as a gas in the Earth’s atmosphere and is one of the by-products of combustion, it does not harm the Earth’s stratospheric ozone layer. Its atmospheric lifetime is minimal.
Superior To Other Gas Agents: HFC 227ea® is superior to other gas-based extinguishing agents that have lower boiling points and tend to be corrosive.
High-value Risk Protection :Suitable for protection on a range of high-value risks as it virtually eliminates damage to high-tech equipment, artwork and other delicate and sensitive objects.
No Clean-up Required After Discharge : After a discharge, the extinguishing agent can be removed by simple ventilation.
24-hour Protection: Automatic detection and actuation controls ensure fire protection is always ‘on’.
Multiple Triggers: The system can be triggered either by the manual actuation system or through the automatic detection system.
Speedy Deployment, Minimal Downtime : Deploys quickly, reaching extinguishing levels in 10 seconds or less, stopping ordinary combustible, electrical, and flammable liquid fires before they cause significant damage. When a fire is extinguished this quickly, it means less damage, lower repair costs, and an extra margin of safety for people. It also means less downtime and disruption of business.
Lower Storage Requirements : Stored in cylinders as a liquid and pressurised with nitrogen, HFC 227ea systems takeup to seven times less storage space than any system based on CO2 and inert gases.
Highly Effective: Not only does HFC227ea Flooding System -M work in 10 seconds, it prevents re-ignition by rapidly cooling down temperatures in the surrounding area.
Residue-Free: Being a clean agent, it won’t leave behind oily residue, particulate or corrosive material .
Highly Reliable : A fully assembled and 100% tested mechanical control head ensures reliable operation. A pressure gauge on the steel cylinders marks the gas levels so maintenance staff can replenish it whenever required. Protective chrome nozzle covers keep nozzles free from contamination and blockages by grease or other by-products that could inhibit the proper discharge of the extinguishing agent.
Technical Specification
System Name | Enclosure Volume (Minimum) | Enclosure Volume (Maximum) |
---|---|---|
CF – HFC 227ea Flooding System – M – V1 | 20 m3 | 28 m3 |
CF – HFC 227ea Flooding System – M – V2 | 28.1 m3 | 40 m3 |
CF – HFC 227ea Flooding System – M – V3 | 40.1 m3 | 47 m3 |
CF – HFC 227ea Flooding System – M – V4 | 47.1 m3 | 60 m3 |
CF – HFC 227ea Flooding System – M – V5 | 60.1 m3 | 80 m3 |
CF – HFC 227ea Flooding System – M – V6 | 80.1 m3 | 90 m3 |
CF – HFC 227ea Flooding System – M – V7 | 90.1 m3 | 105 m3 |
CF – HFC 227ea Flooding System – M – V8 | 105.1 m3 | 120 m3 |
* Technical specifications are subject to change with time due to our continuous product improvisation initiatives.
Application Areas
- Offices & Factories
- Server Rooms
- Battery Banks
- Petroleum Storage
- Parking Lots
- Storage Areas
Reviews
There are no reviews yet.